Energy and Water Heating
About 4200 Joules are required to heat 1 litre of water by 1°
Centigrade.
Example 1
1 litre of water is heated with a 2kW kettle from 10°C to 100°C.
2kW means that 2000J are supplied every second.
To raise 1 litre by 90C 378,000J are needed, (4200 x 1 x 90).
This means that a 2kW kettle needs 189 seconds to boil the litre of water.
Example 2
A 30 gallon (130 litre) cylinder is heated from 10C to 60C.
The energy required is;
50C x 4200 x 130 = 27,300,000 J
This is a very large number that doesn’t mean an awful lot, so to convert this to kWhr, simply divide by 3,600,000
= 7.58 kWhrs
a 3kW immersion heater would therefore require 2½ hours to heat the cylinder. 7.58 divided by 3.
Shortcut to quickly work out energy required to heat water.
If we divide 4200 by 3,600,000J we can get a factor to work out how much energy is required in kWhrs.
0.001166
A simple formula now exists
Volume x Change in Temperature x 0.001166 = Energy required in kWhr
Example 3
How much energy is used to heat a 200 litre cylinder from 10C to 57C?
Change in Temperature = 47°C
Volume = 200 litres
Answer= 200 x 47 x 0.001166
= 10.96 kWhr
So a 18kW boiler (60,000 BTU) will be capable of heating this water in
36½ minutes
or a 3kW immersion would take
3 hours 39 minutes
Example 4
A typical daily shower uses 30 litres of water at 39C. If the incoming mains water is at 10C, how much energy is used over the whole year?
Change in temperature = 29C
Volume = 365 x 30 = 10950
Energy in kWhrs = 29 x 10950 x 0.001166 = 370 kWh
Example 5
An 130 litre (30 gallon) uninsulated cylinder in a “hot press” is heated by the central heating every evening from 20C to 60C. It cools overnight to 20C, so that the central heating is required in the morning to re-heat this water. How much energy is wasted by overnight cooling when the heating is used for 300 days per year?
Change in Temperature = 40°C
Volume = 130 x 300
Energy = 40 x 130 x 300 x 0.001166
= 1819 kWhr.
(note that this is almost the annual output of a solar panel).
Note: Replacing a cylinder with a properly insulated cylinder (with lagged pipework) can achieve the similar energy savings as the installation of a solar panel.
Example 6
What size boiler would be required to heat a 1000 litre buffer tank by 10°C in one hour?
Answer
Using the formula, the energy required is
Vx Delta T x 0.001166 = Energy in kWhrs
1000 x 10 x 0.001166 = 11.66 kWhrs
So the boiler would need to be 11.66 kW
If the Boiler was 23.3kW, then the buffer could be heated by 20°C in one hour or 10°C in a half hour.
Example 7
How much energy is required to heat the following;
200 litres from 10°C to 60°C
1000 litres from 20°C to 30°C
300°C from 10°C to 60°C
Answer
Vx Delta T x 0.001166 = Energy in kWhrs
200 x 50x 0.001166 = 11.66 kWhrs
1000 x 10 x 0.001166 = 11.66 kWhrs
300 x 50 x 0.001166 = 17.49 kWhrs
These are very important answers and should be remembered
A 200 litre cylinder heated by 50 C needs about 12kWhrs
A 1000 litres of water heated by 10 C needs about 12kWhrs
A 300 litre cylinder heated by 50C needs about 18kWhrs
Water Content of Copper Tubes
|
Nominal Size (mm)
|
Water Content per Meter (Litres)
|
|
8
|
0.036
|
|
10
|
0.055
|
|
15
|
0.145
|
|
22
|
0.320
|
|
28
|
0.539
|
|
35
|
0.835
|
|
42
|
1.232
|
Example 8
A solar panel is installed with a total of 30 meters of pipework (15m flow and 15m return). Calculate the volume of heat transfer fluid contained in the pipework. Calculate for 10mm, 15mm and 22mm.
Secondly, if the pipework cools from 50°C to 20°C at night, calculate the energy lost each night the solar panel is running.
Thirdly, assume that the solar panel runs 300 days per year and produces 2000kWh. What is the percentage efficiency drop caused by the volume of liquid in the pipework cooling. Calculate for 10mm, 15mm and 22mm.
Answer
|
Nominal Size (mm)
|
Water Content per Meter (Litres)
|
Content in 30 Meters
|
|
10
|
0.055
|
1.65
|
|
15
|
0.145
|
4.35
|
|
22
|
0.320
|
9.60
|
Water in pipework cools by 30°C
Energy in kWhrs = Volume (V) x Change in Temp (Δt) x 0.001166
(This figure means 1000Joules every second for 1 hour, i.e. 3600 seconds)
10mm pipe = 30 x 1.65 x 0.001166= 0.0577 kWhrs per day
15mm pipe = 30 x 4.35 x 0.001166 = 0.1521 kWhrs per day
22mm pipe = 30 x 9.60 x 0.001166 = 0.3358 kWhrs per day
If the panel runs for 300 days per year and creates 2000 kWhrs of energy, then
for
10mm pipe: 0.0577 kWhrs per day x 300 = 17.31 kWhrs
15mm pipe: 0.1521 kWhrs per day x 300 = 45.63 kWhrs
22mm pipe: 0.3358 kWhrs per day x 300 = 100.74 kWhrs
This equates to an efficiency drop as follows
17.31 x 100% = 0.87% (10mm pipe)
2000
45.63 x 100% = 2.28% (15mm pipe)
2000
100.74 x 100% = 5.03% (22mm pipe)
2000
Units of Energy and Oil.
As can be seen from the index page above Heating oil contains about 10.6 kWhrs
per litre and produces 3.02 kg of CO2 when burned.
A lot of people are surprised to find that a litre of oil weighing about 900g is
transformed into over 3kg of CO2, this is because as oil is burned the chemical reaction
takes Oxygen from the air (a heavy molecule) and combines with the carbon (a light molecule)
so the net result is the high weight of CO2.
Example 5 revisited
In Example 5 above, the wasted 1819 kWhrs would equate to 171.4 litres of oil.
But only if burned in a 100% efficient boiler.
An typical efficiency might be 80%, so in actual fact the litre of oil is only supplying about 8.48 kWhrs of energy. So the cylinder in example 5 is actually wasting 214.5 litres of oil per year.
In CO2 terms this equates to 647.8 kg
In fact, the energy wastage would possibily be much higher, in many cases heating zones are not installed or working correctly and the complete house is heated to provide hot water generated for showers.
Another overlooked important energy wasteage is the pipe run between the boiler and the cylinder. This is often poorly lagged and very wasteful of energy.
So poor is this performance, is that some solar simulation packages use a default boiler efficiency of just 55% when calculating water heating compared with 80% for the heating system.
Other units of Energy
Example 9
Calculate the kWhr and Oil equivalent of a 3000 kCal a day diet.
Answer
If there are 4200 joules in one kcalorie.
4,200 x 3000 = 12,600,000 Joules
to convert to kWhrs divide by 3,600,000
= 3.5 kWhrs 
or in terms of oil divide by 10.08 (See table)
= 0.35 litres of Oil
The importance of these calculations will be seen in the analysis of the losses in the system,
as a means to optimise the solar yield from the collectors.
|